WITT modular units are based on a 19 inch rack system making it possible to customise the complete assembly and provide a tailor made solution for supplying services to a given point of use - mobile or stationary
Outlet points
Based on 19 inch racks
19 inch – rack for shielding gas with up to 5 integrated outlet points consisting of:
- Witt dome loaded pressure regulator and metering
valve (0-30 l/min, 0-63scfh) or flow meter for outlet points
- 2/2 way ball valves or 3/2 way ball valves (changing
between two shielding gases) per outlet points
- hose couplings according to EN 561 / ISO 7289
19 inch – rack with integrated gas mixer for 2 or 3 gases
19 inch – rack with integrated gas analysis and documentation
19 inch rack for acetylene (flammable gases) and oxygen for up to 2 integrated outlet points per gas consisting of:
- pressure regulator
- flashback arrestor according to EN 730 / ISO 5175
- 2/2 way ball valves per outlet point
- hose couplings according to EN561 /ISO 7289
19 inch rack for compressed air with up to 5 integrated outlet
points consisting of:
- pressure regulator
- 2/2 way ball valves per outlet point
- hose couplings with manual venting system
Other versions are available