Favourites

Dome Pressure Regulator 767LE/S-ES, complete solution

Data sheet Quotation request

High-performance dome-loaded pressure regulator for very high flows

  • Kv value 30
  • maximum pressure stability also in case of withdrawal fluctuations
  • outlet pressure 0.5-30 barg
  • also suitable for various aggressive and toxic gases
  • ready-to-use
  • connections: G 3″ IG, Flange DN 80/100

For technical backgrounds and lots more about dome-loaded pressure regulators, please see: domepressureregulators.com

  • Information
  • Downloads

Powerful and low-maintenance Dome Pressure Regulator applicable for mounting in pipeworks.

Benefits:

  • high pressure stability even when subject to fluctuations in withdrawal enables process reliability
  • Pilot Control Tube (PCT) for particularly high constant outlet pressure
  • applicable for almost all gases
  • accurate dynamic regulation
  • high flow rate
  • Balanced Seat Design (BSD) for better control precision
  • complete mounted, inclusive pressure gauge, pilot pressure regulator and fittings
  • working pressure changable at any given moment  (readjustable) – e.g. due to temperature fluctuations
  • provides constant working pressure by dynamic control
  • no disperse of pilot gas to the environment – closed system
  • pressure gauges optionally in stainless steel and/or filled with glycerine
  • indoor and outdoor installation
  • connection for wall mounting panel
  • easy installation and removing
  • inlet-/outlet fitting with flange DN 80 or DN 100, PN 16/40, DIN 2656 with O-ring 88.5x3 mm

Options:

  • control via electrical proportional valve
  • piloting by foreign gas available
  • filter

Operation / Usage:

  • Dome pressure regulator are especially suitable for process supply in pipe-works and system engineering.
  • Independent of withdrawal fluctuations the stability working pressure guarantees a constant gas concentration and quality of the down stream processes.
  • Additionally the use in case of high flow rates at low pressure drops is recommended.

Function:

  • The dome pressure regulator is used in combination with pilot pressure regulator (or proportional valve) for adjusting the required working pressure (outlet pressure).
  • It’s possible to use the regulated gas (own medium) or foreign gas as supply of pilot pressure regulator by option.

Maintenance:

  • Annual testing of body leak tightness is recommended.
  • Replace wearing parts at least every 1-3 years.
  • Premounted Maintenance-Kit on request.

Approvals
Company certified to ISO 9001, ISO 22000 and PED 97/23/EC Module H

For technical backgrounds and lots more about dome-loaded pressure regulators, please see: domepressureregulators.com

Products

WITT Zentrale

Give us a call!

Headquarters: +49 (0)2302-8901-0
WITT UK: +44 (0)1925 234466

Send request Get callback