Flashback Arrestor RF53DN

Flashback Arrestor RF53DN for fuel gases

Data sheet Quotation request

Universal flashback arrestor, certified to EN 730-1 / ISO 5175, with pressure relief valve [RV]

  • highest quality from the world market leader
  • safety elements: flame arrestor [FA], temperature-sensitive cut-off valve [TV], non-return valve [NV], filter on gas inlet, pressure relief valve
  • every arrestor 100% tested
  • BAM certified
  • 25,5 X 101 mm, 260 g
  • acetylene max. 11,5 m³/h (free flow-off)
  • fuel gases max. 105 m³/h (free flow-off)
  • oxygen max. 56 m³/h (free flow-off)
  • Information
  • Applications
  • Downloads
  • Accessories

WITT RF Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with EN 730-1 / ISO 5175. Every Arrestor 100% tested.

The best Flashback Arrestors in the world

  • a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
  • a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
  • a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
  • a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
  • a pressure relief valve vents excessive pressure and soot into the atmosphere, protecting the hose from bursting and the flame arrestor from clogging up, thus maintaining the flow rate

Operation / Usage:

  • RF Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
  • for pipeline outlets and single cylinders
  • WITT Flashback Arrestors may be mounted in any position / orientation
  • only one piece of equipment may be connected to a single Flashback Arrestor
  • the maximum ambient / working temperature is 70 °C / 158 °F

Maintenance:

  • annual testing of the check valve, body leak-tightness and flow capacity is recommended
  • WITT is happy to supply special test equipment
  • Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced by competent staff

Approvals:
Company certified to ISO 9001
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems

Flashback Arrestor RF53DN is used in following areas:

Fittings

For hose or pipe connection PN 10

Test Rig 722

For the annual testing of WITT flashback arrestors and non-return valves

Pipe Connection WITT-FIX

Pipe couplings for copper and stainless steel pipelines up to 25 bar working pressure

Products

WITT Zentrale

Give us a call!

Headquarters: +49 (0)2302-8901-0
WITT UK: +44 (0)1925 234466

Send request Get callback