Flashback Arrestor 85-30 SMART

Smart flashback arrestor, according to DIN EN ISO 5175-1, patented, for maximum flows

  • highest quality from the world market leader
  • safety elements: flame arrestor [FA], temperature-sensitive cut-off valve [TV], non-return valve [NV], filter on gas inlet
  • smart features for process optimisation: real-time detection of flashbacks and backfire
  • every arrestor 100% tested
  • 95 X 213 mm
  • acetylene max. 70 m³/h (free flow-off)
  • fuel gases max. 675 m³/h (free flow-off)
  • oxygen max. 860 m³/h (free flow-off)

This model is also available in Stainless Steel

Data sheet Downloads
Quotation request

Information

WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks according to DIN EN ISO 5175-1, combined with high-tech sensors and electronic components.
Every Arrestor 100% tested.
The Flashback Arrestor 85-30 SMART indicates via LEDs its current status. The signal is then transmitted to a control system. Status is communicated in real-time.
This is key contribution to accident prevention and process.

PATENTED
 

Features of Flashback Arrestor 85-30

  • according to PED 2014/68/EU, connection G1.1/2 category I
  • available in brass or stainless steel (ES)
  • a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback
  • a temperature sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
  • a spring loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
  • a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life

Smart Features

  • any flashback or backfire is detected electronically and recorded as a timestamped event
  • four LEDs provide a visual all-round indication of normal operation, flashback, backfire, hardware faults and low battery via red/green/yellow/blue diodes located directly on the safety device
  • digital signal via a NPN open collector signal or RS485 for transmission to a control system
  • reset button on the safety device for resetting or acknowledging the system following a flashback or backfire
  • connection M8, 4-pin plug for signal cable 5 m (Art.-No. 803097000)
  • not suitable for use in hazardous areas

Benefits

  • immediate detection of flashbacks and backfires
  • early detection of sources of faults before other downstream system components are damaged
  • planning framework for optimised maintenance work
  • minimises downtime, increases service life – reduces operating costs
  • maximum protection for staff and facilities

Approvals
Company certified according to ISO 9001 and PED 2014/68/EU Module H
CE-marked according to PED 2014/68/EU
Designed for Oxygen Service in accordance with EIGA 13/20 and CGA G-4.4: Oxygen Pipeline and Piping Systems
Cleaned for Oxygen Service in accordance with EIGA 33/18 and CGA G-4.1: Cleaning of Equipment for Oxygen Service

Downloads

Here you find all downloads for the product.