Flashback Arrestor 85-10NU (eccentric) | wittgas.com

Favorites

Flashback Arrestor 85-10NU (eccentric)

Witt Flashback Arrestor 85 10nu Ecc Fuel Gases

Witt Flashback Arrestor 85 10nu Ecc Fuel GasesWitt Flashback Arrestor 85 10nu Ecc Fuel Gases
Witt Flashback Arrestor 85 10nu Ecc OxygenWitt Flashback Arrestor 85 10nu Ecc Oxygen
Data sheet Quotation request

Flashback arrestor, certified to DIN EN ISO 5175-1, for high-performance torches, off-center connection

  • highest quality from the world market leader
  • safety elements: flame arrestor [FA], check valve [NV], temperature-controlled cut-off valve [TV], filter on gas inlet
  • every arrestor 100% tested
  • 1.34 X 3.9 - 4.65 inches, 14.7 oz
  • acetylene max. 776 scfh (free flow-off)
  • fuel gases max. 8,295 scfh (free flow-off)
  • oxygen max. 10,942 scfh (free flow-off)

     

Information

WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with to DIN EN ISO 5175-1. Every Arrestor 100% tested.

The best Flashback Arrestors in the world

  • a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
  • a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
  • a spring-loaded check valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply

Operation / Usage:

  • Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
  • for torches or burners with high flow: Models 85-10NU and 85-10 eccentric = eccentric outlet
  • WITT Flashback Arrestors may be mounted in any position /orientation
  • only one piece of equipment may be connected to a single Flashback Arrestor
  • the maximum ambient / working temperature is 70 °C / 158 °F

Maintenance:

  • annual testing of the check valve, body leak-tightness and flow capacity is recommended
  • WITT is happy to supply special test equipment
  • Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced according to model by competent staff

Approvals

Company certified to ISO 9001 and PED 2014/68/EU Module H
CE-marked according to PED 2014/68/EU
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems

Downloads

Here you find all downloads for the product.

Applications

Flashback Arrestor 85-10NU (eccentric) is used in following areas:

Products

Give us a call!

Headquarters: +49 (0)2302-8901-0
WITT USA: +1 770-664-4447

Quotation request Get call-back

Expert advice

You need advice?
We call you back!

Request call-back now