Non-Return Valve NV654

Non-return valve for the prevention of unintended gas mixtures, for flow rates up to 11,059 scfh (air), up to 870 psi, G 1/8

  • safety element: non-return valve [NV]
  • every non-return valve 100% tested
  • ultra-low opening pressures (approx. 0.435 psi), ultra-low pressure drop
  • small and light: 0.55 X 1.64 inches, 1.56 oz
  • up to 870 psi working pressure (O2: up to 435 psi)
  • air max. 11,059 scfh (free flow-off)

This model is also available in Stainless Steel

    Data sheet Downloads
    Quotation request

    Information

    WITT  non-return valves (check valves) for reliable protection against dangerous reverse gas flow. Every  non-return valve (check valve) 100% tested.

    Benefits:

    • a spring-loaded  non-return valve (check valve) prevents a reverse flow of gases which could lead to unwanted gas mixtures
    • low pressure drops – using complex valve assembly with low opening pressures (approx. 30 mbar)
    • no leaks – using a spring-loaded valve assembly with elastomer sealing
    • diverse applications – useful for many technical gases
    • reduce installation costs – the spring-loaded valve is not affected by gravity and may be installed in any orientation
    • compact design, small mounting dimensions

    Operation / Usage:

    • non-return valves (check valves) are used to protect equipment and pipelines against dangerous reverse gas flow
    • WITT  non-return valves (check valves) may be mounted in any position / orientation
    • the maximum ambient / working temperature is 60 °C / 140 °F

    Maintenance:

    • annual testing of the  non-return valve (check valve) and body leak tightness is recommended
    • WITT is happy to supply special test equipment
    • non-return valves (check valves) are only to be serviced by the manufacturer

    Approvals
    Company certified to ISO 9001 and PED 2014/68/EC Module H
    Designed for Oxygen Service in accordance with EIGA 13/20 and CGA G-4.4: Oxygen Pipeline and Piping Systems
    Cleaned for Oxygen Service in accordance with EIGA 33/18 and CGA G-4.1: Cleaning of Equipment for Oxygen Service

    Downloads

    Here you find all downloads for the product.

    Accessories

    Test Rig 722

    Test Rig 722

    For the annual testing of WITT flashback arrestors and check valves