Flashback Arrestor 85-30
Flashback arrestor, certified to DIN EN ISO 5175-1, standard for maximum flows
- highest quality from the world market leader
- safety elements: flame arrestor [FA], temperature-sensitive cut-off valve [TV], non-return valve [NV], filter on gas inlet
- every arrestor 100% tested
- 84 X 162/188 mm, 4.580 g
- acetylene max. 70 m³/h (free flow-off)
- fuel gases max. 675 m³/h (free flow-off)
- oxygen max. 860 m³/h (free flow-off)
This model is also available in Stainless Steel
Information
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and
flashbacks according to DIN EN ISO 5175-1. Every Arrestor 100% tested.
The best Flashback Arrestors in the world
- a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
- a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
- a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
- a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
Operation / Usage:
- Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
- for pipeline outlets and single cylinders with high users for example supply units for gas cutting machines
- WITT Flashback Arrestors may be mounted in any position /orientation
- only one piece of equipment may be connected to a single Flashback Arrestor
- the maximum ambient / working temperature is 60 °C / 140 °F
- gases: acetylene, town gas, natural gas, LPG, hydrogen, oxygen, compressed air, ethylene (more upon request)
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced by competent staff
Approvals
Company certified to ISO 9001 and PED 2014/68/EC Module H
CE-marked in accordance with PED 2014/68/EC
Designed for Oxygen Service in accordance with EIGA 13/20, CGA G-4.4 and AIGA 021/20: Oxygen Pipeline and Piping Systems
Cleaned for Oxygen Service in accordance with EIGA 33/18, CGA G-4.1 and AIGA 012/19: Cleaning of Equipment for Oxygen Service