Vlamdover 85-30
Vlamdover volgens de DIN EN ISO 5175-1, Standaard voor maximale flow
- hoogste kwaliteit van de wereldmarktleider
- beveiligingselementen: vlamdover [FA], thermisch gestuurde afsluiter [TV], gaskeerklep [NV], filter in de gasingang
- ieder appendage wordt 100% getest
- 84 X 162/188 mm, 4.580 g
- Acetyleen max. 70 m³/h (vrije uitstroom)
- Brandbare gassen max. 675 m³/h (vrije uitstroom)
- Zuurstof max. 860 m³/h (vrije uitstroom)
Informatie
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and
flashbacks according to DIN EN ISO 5175-1. Every Arrestor 100% tested.
The best Flashback Arrestors in the world
- a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
- a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
- a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
- a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
Operation / Usage:
- Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
- for pipeline outlets and single cylinders with high users for example supply units for gas cutting machines
- WITT Flashback Arrestors may be mounted in any position /orientation
- only one piece of equipment may be connected to a single Flashback Arrestor
- the maximum ambient / working temperature is 60 °C / 140 °F
- gases: acetylene, town gas, natural gas, LPG, hydrogen, oxygen, compressed air, ethylene (more upon request)
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced by competent staff
Approvals
Company certified to ISO 9001 and PED 2014/68/EC Module H
CE-marked in accordance with PED 2014/68/EC
Designed for Oxygen Service in accordance with EIGA 13/20, CGA G-4.4 and AIGA 021/20: Oxygen Pipeline and Piping Systems
Cleaned for Oxygen Service in accordance with EIGA 33/18, CGA G-4.1 and AIGA 012/19: Cleaning of Equipment for Oxygen Service
147-081
147-072
147-069
147-001
147-003
147-065
147-068
Downloads