Non-Return Valve NV2000
Non-return valve for the prevention of unintended gas mixtures, for flow rates up to 26800 m³/h (air), for use in thermal processing plants, certified to EN746-2, DN 80-200
- safety element: non-return valve [NV]
- every non-return valve 100% tested
- ultra-low opening pressures (approx. 5 mbar), ultra-low pressure drop
- dirt filter (100 μm) in the gas inlet
- to be mounted in vertical position / orientation
- in accordance with EN 746-2
- 320-340 X 393-450 mm, 50 kg
Information
WITT non-return valves for reliable protection against dangerous reverse gas flow.
Every non-return valve 100% tested.
Benefits:
- a spring-loaded non-return valve prevents a reverse flow of gases which could lead to unwanted gas mixtures
- low pressure drops – using complex valve assembly with low opening pressures, NV2000 approx. 5 mbar
- no leaks – using of a spring-loaded valve assembly with elastomer sealing
- stainless steel filter (100 μm) in the gas inlet protects the non-return valve against dirt contamination, extending the service life
- diverse applications – useful for many technical gases
Operation / Usage:
- non-return valves are used to protect equipment and pipelines against dangerous reverse gas flow. Use is possible for applications in accordance with EN 746-2
- the NV2000 may be mounted vertical in bottom-up flow direction
- the maximum ambient / working temperature is 70 °C / 158 °F
Maintenance:
- annual testing of the non-return valve and body leak tightness is recommended
- WITT is happy to supply special test equipment
- non-return valves are only to be serviced by the manufacturer
Approvals
Company certified to ISO 9001 and PED 2014/68/EU Module H
CE-marked in accordance with PED 2014/68/EU
Designed for Oxygen Service in accordance with EIGA 13/20 and CGA G-4.4: Oxygen Pipeline and Piping Systems
Cleaned for Oxygen Service in accordance with EIGA 33/18 and CGA G-4.1: Cleaning of Equipment for Oxygen Service
Downloads
Here you find all downloads for the product.