Flashback Arrestor Super 90 | wittgas.com

Favorites

Flashback Arrestor Super 90

Flashback Arrestor Super 90

Flashback Arrestor Super 90Flashback Arrestor Super 90
Flashback Arrestor Super 90Flashback Arrestor Super 90
Video WITT Flashback ArrestorsVideo WITT Flashback Arrestors
Data sheet Quotation request

Resettable Flashback arrestor, certified to DIN EN ISO 5175, with pressure sensitive cut-off valve [PV] and visual warning

  • highest quality from the world market leader
  • safety elements: flame arrestor [FA], temperature-sensitive cut-off valve [TV], check valve [NV], filter on gas inlet, pressure sensitive cut-off valve [PV]
  • stops supply of fuel gas in case of flashback and shows visual warning that flashback has occured, easy to reset
  • every arrestor 100% tested
  • 2.5 X 4.7 inches
  • acetylene max. 388 scfh (free flow-off)
  • fuel gases max. 4,518 scfh (free flow-off)
  • oxygen max. 2,188 scfh (free flow-off)

     

Information

WITT Super Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with DIN EN 5175-1/DIN EN 5175-2. Every Arrestor 100% tested.

The best Flashback Arrestors in the world

  • a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
  • after any flashback or reverse gas flow, a pressure-sensitive cut-off valve PV immediately cuts off the gas supply and prevents dangerous further work
  • a red signal lever indicates the operation of the pressure-sensitive cut-off valve
  • the resetting of the arrestor via the lever allows the user to resume safe work immediately after fixing the cause of the flashback or the reverse gas flow
  • a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
  • a spring-loaded check valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
  • a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
  • a pressure relief valve RV vents excess pressure and soot into the atmosphere, protecting the hose from bursting and the flame arrestor from clogging up, thus maintaining the flow rate

Operation / Usage:

  • Super Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
  • WITT Flashback Arrestors may be mounted in any position /orientation
  • only one piece of equipment may be connected to a single Flashback Arrestor
  • the maximum ambient / working temperature is 70 °C / 158 °F

Maintenance:

  • annual testing of the non-return valve, body leak tightness and flow capacity is recommended
  • WITT is happy to supply special test equipment
  • Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced by competent staff

Approvals
Company certified to ISO 9001
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems

 

125-030

125-029

Downloads

Here you find all downloads for the product.

Applications

Flashback Arrestor Super 90 is used in following areas:

Products

Give us a call!

Headquarters: +49 (0)2302-8901-0
WITT USA: +1 770-664-4447

Quotation request Get call-back

Expert advice

You need advice?
We call you back!

Request call-back now