Vlamdover 85-20
Standaard vlamdover volgens de DIN EN ISO 5175-1 voor grotere flow
- hoogste kwaliteit van de wereldmarktleider
- beveiligingselementen: vlamdover [FA], thermisch gestuurde afsluiter [TV], gaskeerklep [NV]
- ieder appendage wordt 100% getest
- 62 X 131/137 mm, 1400-1500 g
- Acetyleen max. 45 m³/h (fvrije uitstroom)
- Brandbare gassen max. 324 m³/h (vrije uitstroom)
- Zuurstof max. 333 m³/h (vrije uitstroom)
Dit model is ook in RVS leverbaar
Informatie
WITT Flashback Arrestors for reliable protection against dangerous reverse gas flow and
flashbacks in accordance with DIN EN ISO 5175-1. Every Arrestor 100% tested.
The best Flashback Arrestors in the world
Benefits:
- a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
- a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
- a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
Operation / Usage:
- Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
- for pipeline outlets and single cylinders with high users for example supply units for gas cutting machines
- WITT Flashback Arrestors may be mounted in any position /orientation
- only one piece of equipment may be connected to a single Flashback Arrestor
- the maximum ambient / working temperature is 60 °C / 140 °F
- gases: acetylene, natural gas, hydrogen, oxygen, ethylene, propane, compressed air (more upon request)
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- Flashback Arrestors are only to be serviced by the manufacturer
Approvals
Company certified to ISO 9001 and PED 2014/68/EC module H
CE-marked in accordance with PED 2014/68/EC
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping
Downloads
Hier vindt u de belangrijkste downloads van het product