Vlamdover Super 66
Resetbare vlamdover volgens de DIN EN ISO 5175 met waarschuwingsmelding en een maximum aan beveilignselementen, hoge flow
- hoogste kwaliteit van de wereldmarktleider
- Beveiligingselelementen: vlamdover [FA], thermisch gestuurde afsluiter [TV], gaskeerklep [NV], filter in de gasingang en drukgestuurde thermische beveiliging [PV]
- onderbreekt de brandbare gastoevoer bij vlamterugslag en geeft een waarschuwingssignaal, eenvoudig weer in grebruik te nemen
- ieder appendage wordt 100% getest
- BAM gecertificeerd
- 63 X 160 mm, 1.104 g
- Acetyleen max. 20 m³/h (vrije uitstroom)
- Brandbare gassen max. 225 m³/h (vrije uitstroom)
- Zuurstof max. 105 m³/h (vrije uitstroom)
Informatie
WITT Super Flashback Arrestors for reliable protection against dangerous reverse gas flow and flashbacks in accordance with DIN EN 5175-1/DIN EN 5175-2. Every Arrestor 100% tested.
The best Flashback Arrestors in the world
- a large surface area flame arrestor FA of stainless steel construction extinguishes any dangerous flashback entering the device in any direction
- after any flashback or reverse gas flow, a pressure-sensitive cut-off valve PV immediately cuts off the gas supply and prevents dangerous further work
- a red signal lever indicates the operation of the pressure-sensitive cut-off valve
- the resetting of the arrestor by the lever allows the user to resume safe work immediately after fixing the cause of the flashback or the reverse gas flow
- a temperature-sensitive cut-off valve TV extinguishes sustained flashbacks long before the internal temperature of the arrestors reaches a dangerous level
- a spring-loaded non-return valve NV prevents slow or sudden reverse gas flow from forming explosive mixtures in the gas supply
- a filter at the gas inlet protects the arrestor against dirt contamination, extending the service life
- a pressure relief valve RV vents excess pressure and soot into the atmosphere, protecting the hose from bursting and the flame arrestor from clogging up, thus maintaining the flow rate
Operation / Usage:
- Super Flashback Arrestors are used to protect gas cylinders and pipeline outlet points (hoses and any equipment) against dangerous reverse gas flow and flashbacks
- WITT Flashback Arrestors may be mounted in any position /orientation
- only one piece of equipment may be connected to a single Flashback Arrestor
- the maximum ambient / working temperature is 60 °C / 140 °F
- gases: acetylene, town gas, natural gas, LPG, hydrogen, oxygen, compressed air, ethylene (more upon request)
Maintenance:
- annual testing of the non-return valve, body leak tightness and flow capacity is recommended
- WITT is happy to supply special test equipment
- Flashback Arrestors are only to be serviced by the manufacturer; the dirt filter may be replaced by competent staff
Approvals
Company certified to ISO 9001
Cleaned for Oxygen Service according to EIGA IGC Doc 13/12/E: Oxygen Pipeline and Piping Systems
Downloads
Hier vindt u de belangrijkste downloads van het product